AquaControl-difference-controller III
AquaControl-difference-controller III
The classic for wood stove control
The AquaControl-difference-controller III is the smaller version of the MasterControl. It is used when a wood stove with boiler function operates without the solar system. The wood stove is wired in series connection to the tank. Achieving the necessary operating temperature at the heating device, the temperature difference-controller controls the AquaLoadPump and the 3-way-cross-valve, using 2 rotational speed controlled relay output and 4 sensor inputs.
It is controlled by three buttons and a LCD display with four pre-installed basic schemes. Other functions: anti lock for wood stove pump, max. temperature limit, target temperature control, time switch for cross valve, operating hour counter.
Delivery info
The accessories include the wall mount and 4 sensors.
Technical details
Height | 172 mm |
Width | 110 mm |
Depth | 46 mm |
Switching outputs | 2 Halbleiterausgänge + 2 PWM-Ausgänge |
Sensor inputs | 4 x PT 1000 |
Temperature sensor | 4 Stück PT 1000 |
Installation | Wandmontage, Schalttafeleinbau möglich |
Anzeige | LC-Monitoring-Display mit Textunterstützung |
Bus | Resol VBus |
Switching capacity | 1 (1) A 240V |
Order numbers
AquaControl-difference-controller III | 9213 22 |